BVV

BVV™ VE280 9CFM Two Stage Vacuum Pump - 110v

SKU: VE280
  • Sale
  • Regular price $399.00
Shipping calculated at checkout.

Time to choose the lenses that are right for you
What type of lenses do you need *
We need to get your bifocal or varifocal lenses right, this is how it works *
When you order bifoclas or varifocals we send the frames out to you before making your prescription lenses. You will use the frames to take some important measurments. Next, you'll send back your frames free of charge so that we can produce your perfect prescription lenses. We know some other websites don't do this, but we think it's important to get your glasses right. Any questions, please do contact us!
What numbers do you need to provide us with from your prescription? *
Please select all of the numbers you can see information for on your prescription.
Right Sphere (SPH) *
Left Sphere (SPH) *
Right Cylinder (CYL) *
Left Cylinder (CYL) *
Right Axis (AXI) *
Left Axis (AXI) *
Right Near/reading addition (ADD) *
Left Near/reading addition (ADD) *
Right Addition (ADD) Intermediate *
Left Addition (ADD) Intermediate *
We need to provide you with a personal quote. *
Your prescription is slightly outside of the standard range for getting an online order right. We would like to provide you with the perfect pair of glasses, at an affordable price. Please contact us using the details on our website and we can provide you with an affordable quote that best meets your needs. It's quick, easy and it mean you'll get the right glasses for you.
Do you have one or two Pupillary Distance (PD) values? *
Some people might see more that one PD number on their prescrition. Measuring your PD is important and easy, please see our 'how to measure your PD' help section. If you do not add a PD measurement we will use the standard average 63mm for men and 60mm for women.
Pupillary Distance (PD) *
Pupillary Distance (PD) - RIGHT *
Pupillary Distance (PD) - LEFT *
Have a prism value on your prescription? *
OD - Left Direction *
OD - Left Power *
OD - Right Direction *
OD - Right Power *
Add transitions lenses? *
Transition lenses are the lenses that darken in the sunlight and lighten in softer light or the dark. They offer both style and convenience, and can help protect your eyes from UV. Our lenses use genuine Transitions technology.
What colour transitions lenses would you like? *
Would you like to add Blue Shield Technology? *
Blue shield technology includes a blue light blocker to reduce exposure to potentially harmful light from extended periods using electronic devices like phones, tablets and laptops. It also includes an anti-reflective coating to reduce glare and increase the amount of visible light passing through the lens. Plus toughened surfaces reduce the amount and effect of scratches.
Choose your lens package *
Want to add UV 400 protection? *
UV400' refers to UV rays at the top end of the UV spectrum, up to the 400-nanometre wavelength. Sunglasses with this level of protection block an even wider spectrum than the CE and British Standard models, making them the ultimate protection for your eyes.
Want to add a tint to your lenses? *
What colour tint would you like to add? *
How dark would you like your tint to be? *
How dark would you like your tint to be? *
How dark would you like your tint to be? *
How dark would you like your tint to be? *
How dark would you like your tint to be? *
How dark would you like your tint to be? *
Just to check *
I confirm that my prescription is correct with the correct values entered, my prescription is not over 2 years old, I am over 16 years of age, and that I am neither registered blind or partially sighted. I have read and agree to the Terms of Sale.
 More payment options

This is the BVV™ Brand VE280 9CFM Two Stage Vacuum Pump.

Key Features:

    • Internal Check Valve
    • Oil Mist Filter Cap
    • Larger Oil Reservoir for longer Oil life
    • Lightweight
    • Rubber Feet for noise dampening
    • Reliable, Economical and Efficient.

 

Specifications:

Free Air Dispalcement - (CFM) 9CFM
# Of Stages 2
Voltage 110v / 60Hz
Ultimate Vacuum 25 Micron
HP 1
Oil Capacity 560ml
Weight 38LB
Intake Connection 1/4" SAE, 3/8" SAE

Performance Chart

Pump Warranty Information

• Customers using solvents such as stabilization resins (MinWax™, Gator Venom™ etc.), alcohol and other polar solvents must use the vacuum pumps in conjunction with a cold trap for evacuations in excess of 5 minutes. (Excludes Cactus Juice™)• If the consumer is using the pump for prolonged periods of time exceeding 5 minutes we require that a cold trap is used or the pump warranty is void.• These stabilization resins have the ability to break down the internal components of the pump that are plastic resulting in a seized motor voiding all warranties. • When evacuation exceeds 5 minutes these solvents begin to vaporize and then re-condense in the vacuum pump reservoir. Once enough solvent re-condenses in the pump displacing the oil the plastic internal components may begin to warp, melt or seize. The use of a cold trap will condense the vapors prior to making their way to the vacuum pump preventing pump damage due to excessive use. Furthermore, Minwax Wood Hardener™ is not to be used with any vacuum pumps, EVER. (A seized motor will result within the first use.)• To prevent these issues from happening to your process, change the Oil after each vacuum pump use, Even if the use time is only 5min.